Flow characteristics of a 12-in. intermittent supersonic tunnel /
by A. Anderson.
Description
- Language(s)
-
English
- Published
-
Arnold Air Force Station, Tennessee : Arnold Engineering Development Center, Air Force Systems Command, United States Air Force, 1963.
- Summary
-
A compilation has been made of all calibration data obtained since 1958 in the von Karman Gas Dynamics Facility's 12-Inch Supersonic Tunnel (D). Test section flow characteristics are presented for the nominal Mach number range from 1.5 to 5 over the available Reynolds number range. Along the axis of the test section for all contours the maximum variation in Mach number is within =0.01, and the average flow angles in pitch and yaw are less than 0.2 deg. Somewhat larger variations in Mach number and flow angularity are found off-axis. At the higher Mach numbers, significant changes in the average test section Mach number with decreasing Reynolds number are accompanied by corresponding changes in the tunnel boundary layer. (Author).
- Note
-
"September 1963."
- Physical Description
-
37 pages :
illustrations,
28 cm
Viewability
Item Link |
Original Source |
Full view
|
Technical Report Archive & Image Library
|