Oxygen transport through hemoglobin solutions

LDR 02951cam a2200409Ii 4500
001 102892461
003 MiAaHDL
005 20230928000000.0
006 m d
007 cr bn ---auaua
008 880229s1966 ohua bt f000 0 eng d
027 ‡aAMRL TR 66-19
035 ‡a(MiU)99187625235406381
035 ‡asdr-miu.99187625235406381
035 ‡a(OCoLC)17554358
035 ‡a(GWLA)gwla ocm17554358
040 ‡aAAG ‡beng ‡cAAG ‡dOCLCQ ‡dIUL ‡dOCLCQ ‡dOCLCO ‡dOCLCQ ‡dTRAAL
049 ‡aMAIN
086 0 ‡aD 301.45/32-3:66-19
088 ‡aAMRL TR 66-19
100 1 ‡aHammel, Harold T. ‡q(Harold Theodore), ‡d1921-2005, ‡eauthor.
245 1 0 ‡aOxygen transport through hemoglobin solutions / ‡cby Harold T. Hammel.
264 1 ‡aWright-Patterson Air Force Base, Ohio : ‡bAerospace Medical Research Laboratories, Aerospace Medical Division, Air Force Systems Command, United States Air Force, ‡c1966.
300 ‡aiii, 18 pages : ‡billustrations ; ‡c28 cm.
336 ‡atext ‡btxt ‡2rdacontent
337 ‡aunmediated ‡bn ‡2rdamedia
338 ‡avolume ‡bnc ‡2rdacarrier
490 0 ‡aAMRL-TR ; ‡v66-19
500 ‡a"February 1966."
504 ‡aIncludes bibliographic references (page 18).
520 ‡aScholander discovered that the steady state flux of oxygen through a thin film of water could be enhanced many times by adding hemoglobin to the water. Several authors have ascribed this facilitated flux of oxygen to the diffusion of oxyhemoglobin down its gradient although the details of their formulations have not been rigorously supported by experimental evidence. A series of measurements of oxygen and nitrogen flux through a film of hemoglobin solution were made for which the pO2 and pN2 on6ne side were always 16.5 and 62.5 mm Hg respectively while the pO2 on the other side was increased from 0.5 to 14 mm Hg by adding increasing thicknesses of teflon film to this side. When the facilitated oxygen flux was small, it was found to equal the calculated flux assuming that the oxygen was carried by the diffusing oxyhemoxglobin and that Henry's law and the equilibrium dissociation curve for oxyhemoglobin apply at the two surfaces of the hemoglobin film. When the facilitated oxygen flux was greatest, it was found to be only one half the calculated flux, presumably because the pO2 on the solution side of the gas-solution interface was considerably less than the 16.5 mmHg prevailing on the gas side. (Author).
536 ‡aResearch supported by Aerospace Medical Division, Air Force Systems Command, United States Air Force; report by John B. Pierce Foundation Labortory under contract no. ‡bAF 33(657)-11103.
538 ‡aMode of access: Internet.
650 0 ‡aOxygen ‡xPhysiological transport.
650 0 ‡aOxyhemoglobin.
710 2 ‡aAerospace Medical Research Laboratories (U.S.), ‡esponsor.
710 2 ‡aJohn B. Pierce Foundation, ‡esponsor.
730 0 ‡aTechnical Report Archive & Image Library (TRAIL)
899 ‡a39015095324490
CID ‡a102892461
DAT 0 ‡a20220802101942.0 ‡b20230928000000.0
DAT 1 ‡a20230928062550.0 ‡b2024-07-29T17:35:28Z
CAT ‡aSDR-MIU ‡cmiu ‡dALMA ‡lprepare.pl-004-008
FMT ‡aBK
HOL ‡0sdr-miu.99187625235406381 ‡aMiU ‡bSDR ‡cGWLA ‡pmdp.39015095324490 ‡sMIU ‡199187625235406381
974 ‡bMIU ‡cGWLA ‡d20240729 ‡sgoogle ‡umdp.39015095324490 ‡y1966 ‡rpd ‡qbib ‡tUS fed doc