The NOL 3 megawatt research arc /
by E.M. Winkler [and three others]
Description
- Language(s)
-
English
- Published
-
White Oak, Maryland : United States Naval Ordnance Laboratory, 1964.
- Summary
-
The design and initial performance of a 3 MW electric arc air heater are discussed. This arc will be used as a heat source in a true temperature wind tunnel designed, and currently under construction, for operation at Mach numbers between 3 and 12 at supply pressures of 5 to 150 atmospheres and total energy levels up to 5300 Btu/lb. The arc heater operates on 3-phase a.c. Its components, control systems and instrumentation are described in detail. The initial performance studies were carried out using a Mach number 3 nozzle with the flow expanding into the ambient atmosphere. These tests were carried out at supply pressures up to 45 atmospheres. The highest gas energy level obtained was 7700 Btu/lb. (Author).
- Note
-
Prepared 13 February 1964; published October 1964.
- Physical Description
-
vii, 18 [26,13] pages :
illustrations;
28 cm.
Viewability
Item Link |
Original Source |
Full view
|
Technical Report Archive & Image Library
|